BDE No 154 solution
SIAL/33684 - 50 μg/mL in isooctane, analytical standard
Synonym: 2,2′,4,4′,5,6′-Hexabromodiphenyl ether solution; PBDE 154
CAS Number: 207122-15-4
Empirical Formula (Hill Notation): C12H4Br6O
Molecular Weight: 643.58
EC Number: 208-759-1
MDL Number: MFCD01657488
Linear Formula: C12H4Br6O
Product Type: Chemical
application(s) | environmental |
concentration | 50 μg/mL in isooctane |
format | single component solution |
grade | analytical standard |
InChI | 1S/C12H4Br6O/c13-5-1-9(17 |
InChI key | VHNPZYZQKWIWOD-UHFFFAOYSA |
Quality Level | 100 |
shelf life | limited shelf life, expiry date on the label |
SMILES string | Brc1cc(Br)c(Oc2cc(Br)c(Br |
storage temp. | 2-8°C |
technique(s) | gas chromatography (GC): suitable |
HPLC: suitable |
Application: | BDE No 154 may be used as an analytical reference standard for the determination of the analyte in: • House dust samples using isotope dilution method combined with liquid chromatography coupled to negative ionization atmospheric pressure photoionization tandem mass spectrometry (LC-NI-APPI-MS/MS). • Adipose tissue samples using gas chromatography coupled to ion-trap mass spectrometry (GC-ITMS). |
Application: | Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support. |
General description: | BDE No 154 is a pollutant with low acute toxicity, and belongs to the class of polybrominated diphenyl ethers. It can be commercially used as a flame retardant additive in building materials, textiles, plastics and electronic equipment. |
Other Notes: | The customer needs to make sure that the standard is homogeneous, this can be achieved by shaking, vortexing , or sonicating the ampoule before opening the ampoule. Care should be taken when opening the ampoule to avoid any injuries from the broken glass. The standard should be transferred to a clean and appropriate vial or flask using clean pipettes or micro pipettes. The vial should be immediately capped to avoid any loss or evaporation of the solvent. After opening the ampoule, the standard should not be stored or kept in the ampoule. To preserve the integrity of the product, the standard should be transferred to an appropriate vial that must be capped and stored according to the recommendation on the Certificate of Analysis. |
Symbol | GHS02,GHS07,GHS08,GHS09 |
Signal word | Danger |
Hazard statements | H225 - H304 - H315 - H336 - H410 |
Precautionary statements | P210 - P273 - P301 + P310 + P331 - P302 + P352 |
Hazard Codes | F,Xn,N |
Risk Statements | 11-38-50/53-65-67 |
Safety Statements | 9-16-29-33-60-61-62 |
RIDADR | UN1262 - class 3 - PG 2 - Octanes, solution |
WGK Germany | WGK 2 |
Flash Point(F) | 10.4 °F |
Flash Point(C) | -12 °C |
Storage Temp. | 2-8°C |
UNSPSC | 41116107 |