MVP ICON® ATP Calibrator Set
SIAL/64012BC - MVP ICON®, ATP Luminometer Calibration
Synonym: ATP Calibrator Set; ATP Measurement Calibration Kit; Quality Control ATP Calibrator
Product Type: Chemical
agency | EP |
ISO | |
USP | |
application(s) | food and beverages |
compatibility | for use with MVP ICON instrument |
feature | ready-to-use |
manufacturer/tradename | MVP ICON® |
packaging | set of calibrator rods |
shelf life | 5 yr |
storage condition | protect from light (Keep in a tightlyclosed container, away from any light sources) |
storage temp. | 15-25°C |
Application: | MVP ICON® ATP Calibrator Set is used for performance verification and calibration of the MVP ICON® instrument for rapid monitoring of surface hygiene in the Food and Beverage industries. |
Components: | • One luminescent calibrator • One non-luminescent calibrator |
Features and Benefits: | • On-site calibration • Satisfies HACCP and GMP requirements • No need to send the equipment out to a 3rd party. |
General description: | MVP ICON® ATP Calibrator Set consists of two calibration devices (“rods”) that are used for performance verification and calibration of the MVP ICON® and MVP systems. The luminescent calibrator consists of a 14C radioactive source that emits a very low level (5 x 105 d.p.m., or 0.225 microcuries) of low-energy ß-radiation in a plastic scintillation matrix. This matrix is configured to give constant light output, within 10 % of its original value, at a sufficiently high level to make consistent verification and calibration functions possible over the five‐year life of the calibrator. The non‐luminescent black plastic calibrator provides a reliable low‐end or “dark” source reading. |
Legal Information: | BioControl is a registered trademark of BioControl Systems, Inc. |
Legal Information: | MVP ICON is a registered trademark of Merck KGaA, Darmstadt, Germany |
Other Notes: | Avoid crushing, cutting, or dropping the calibrators. |
Principle: | The luminescent calibrator consists of a 14C radioactive source that emits a very low level (5 x 105 d.p.m., or 0.225 microcuries) of low energy ß radiation in a plastic scintillation matrix. This matrix is configured to give constant light output, within 10% of its original value, at a sufficiently high level to make consistent verification and calibration functions possible over the five- year life of the calibrator. The non-luminescent black plastic calibrator provides a reliable low-end or “dark” source reading. |
Storage and Stability: | To ensure the stability and longevity of the luminescent calibrator, the following precautions must be taken: • Limit Exposure to Light. • Store the luminescent calibrator in the dark or weak ambient light. • If the luminescent calibrator is exposed to bright light before use, insert it in the MVP ICON® or MVP and wait a minimum of 2 minutes before proceeding. • The kit box provided is recommended as an appropriate dark storage. • Do not expose to direct sunlight or intense artificial light before use. |
Suitability: | ATP Testing, Food Processing, HACCP Monitoring, Sanitation |
Testing Method: | ATP Bioluminescence |
RIDADR | NONH for all modes of transport |
WGK Germany | WGK 3 |
Flash Point(F) | Not applicable |
Flash Point(C) | Not applicable |
Storage Temp. | 15-25°C |
UNSPSC | 41122409 |
Components | Luminescent Calibrator Rod; Non Luminescent Calibrator Rod |