SimPlate® Campylobacter CI
SIAL/66006BC - BioControl, Detection and quantification of Campylobacter coli and Campylobacter jejuni in poultry rinses and meat
Synonym: Campy
Product Type: Chemical
application(s) | food and beverages |
compatibility | for use with SimPlate (65009BC) |
form | dry powder |
manufacturer/tradename | BioControl Systems 66006-100 |
material | plastic vial (containing dehydrated culture media) |
shelf life | 6‑18 mo. |
storage condition | dry media |
storage temp. | room temp |
suitability | Campylobacter spp. |
Application: | SimPlate® Campylobacter CI is used in the detection and quantification of Campylobacter coli and Campylobacter jejuni in poultry rinses and meat samples. SimPlate® tests have been validated by international standards (AOAC/MicroVal) |
Components: | 1 package of 50 single-test vials |
Features and Benefits: | • Proprietary chromogenic media and patented plating device with isolation wells combine to produce easily counted results in just 48 hours. • While the traditional agar plate reference method requires the use of 4 Campy CEFEX agar plates to analyze 1 mL sample, SimPlate Campylobacter has been validated to provide equivalent results with just a single plate. Combined with the reduction of necessary sample dilutions, made possible by the broad counting range of the plate (1-738), SimPlate reduces number of tests required for each sample, helping to reduce overall testing costs. |
General description: | SimPlate® Campylobacter CI is designed for the detection and quantification of Campylobacter coli and Campylobacter jejuni. SimPlate® Binary Detection Technology combines proprietary media and a patented plating device to provide fast and accurate quantitative results for key groups of indicator organisms. Defined substrates incorporated into the media are utilized to detect multiple enzymes and redox reactions associated with the target organisms, which results in chromogenic or fluorescent changes to the media, and provides easy-to-read results. Because SimPlate® relies on these key reactions rather than the formation of a colony, results are available days faster than conventional culture methods. |
Legal Information: | Binary Detection Technology is a trademark of BioControl Systems, Inc. |
Legal Information: | SimPlate is a registered trademark of BioControl Systems, Inc. |
Other Notes: | Required for use: SimPlate Device (65009BC) |
Testing Method: | Binary Detection Technology™ |
Symbol | ![]() |
Signal word | Warning |
Hazard statements | H317 - H319 |
Precautionary statements | P261 - P264 - P272 - P280 - P302 + P352 - P305 + P351 + P338 |
RIDADR | NONH for all modes of transport |
WGK Germany | WGK 3 |
Flash Point(F) | Not applicable |
Flash Point(C) | Not applicable |
Storage Temp. | room temp |
UNSPSC | 41106200 |
Components | SimPlate Campylobacter Single Dose, Irradiated |