Advanced Search



Tetraconazole

SIAL/74239 - certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

Synonym: (RS)-2-(2,4-Dichlorophenyl)-3-(1H-1,2,4-triazolyl)propyl 1,1,2,2-tetrafluoroethyl ether; (±)-1-[2-(2,4-Dichlorophenyl)-3-(1,1,2,2-tetrafluoroethoxy)propyl]-1H-1,2,4-triazole

CAS Number: 112281-77-3
Empirical Formula (Hill Notation): C13H11Cl2F4N3O
Molecular Weight: 372.15
MDL Number: MFCD01632314
Linear Formula: C13H11Cl2F4N3O
Product Type: Chemical

Catalog Number PKG Qty. Price Quantity
45-74239-50MG 50 mg
$128.00
1/EA
Add To Favorites

 

form liquid
grade TraceCERT®
  certified reference material
InChI 1S/C13H11Cl2F4N3O/c14-9-1-2-10(11(15)3-9)8(4-22-7-20-6-21-22)5-23-13(18,19)12(16)17/h1-3,6-8,12H,4-5H2
InChI key LQDARGUHUSPFNL-UHFFFAOYSA-N
manufacturer/tradename Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
product line TraceCERT®
Quality Level 100 
  300 
shelf life limited shelf life, expiry date on the label
SMILES string FC(F)C(F)(F)OCC(Cn1cncn1)c2ccc(Cl)cc2Cl
storage temp. 2-8°C
Application: The certified reference material (CRM) is intended to be used as a calibrant for chromatography and other analytical techniques.
Tetraconazole CRM may also be used as given below:

• Multi-residue analysis of 213 pesticides in edible oil samples using an analytical approach combining QuEChERS methodology with gas chromatography-tandem mass spectrometry (GC-MS/MS)
• Multi-residue analysis of 379 pesticides in human serum samples extracted by QuEChERS method― using liquid chromatography-tandem mass spectrometry (LC-MS/MS)
• Detection of 327 multiclass pesticide and 17 veterinary drug residues in eight animal feed samples using liquid- and gas- chromatography combined with tandem mass spectrometry (LC-MS/MS and GC-MS/MS)
• Development of a semi-automated method for the analysis of 261 pesticides and 41 environmental contaminants in catfish muscle samples by QuEChERS sample extraction and low-pressure GC-MS/MS and UHPLC-MS/MS, following an automated robotic micro-SPE clean-up
• Multi-residue analysis of 67 pesticides in olive oil, olives, and avocado samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS) to evaluate various clean-up sorbents
• Method development and validation for the determination of 252 pesticides extracted from surface water samples by solid-phase extraction (SPE) using liquid chromatography quadrupole-orbitrap high resolution tandem mass spectrometry
General description: This certified reference material (CRM) is produced and certified in accordance with ISO/IEC 17025 and ISO 17034. This CRM is traceable to primary material from an NMI, e.g. NIST or NMIJ.
Certified content by quantitative NMR incl. uncertainty and expiry date are given on the certificate.
Download your certificate at: http://www.sigma-aldrich.com.

Tetraconazole is a systemic triazole fungicide― known for its protective, curative, and eradicant activities. It inhibits ergosterol biosynthesis by interfering with the activity of C14-demethylase. It is used for protection against:• Puccinia spp. and Ustilago spp. in cereals
• Eysiphe betae, Cercospora beticola and Uromyces betae in sugar beets
• Podosphaera leucotricha and Venturia spp. in pome fruit
• Erysiphe necator in grapes
• Sphaerotheca fuliginea and Erysiphe cichoracearum in cucurbits
• Sphaerotheca macularis in strawberries
• Leveillula taurica in tomatoes, peppers, and artichokes
• Powdery mildew, rust and scab in vegetables, ornamentals, and tropical fruit
According to the Commission Implementing Regulation (EU) No 540/2011 of 25th May 2011, tetraconazole is approved for use in the European Union (EU) as a plant protection agent, following the Regulation (EC) No. 1107/2009. But maximum residue levels of 0.01 mg/kg to 1 mg/kg are allowed for the presence of tetraconazole in products of plant and animal origin, according to the EU Reg. 2019/1015.
Tetraconazole has to be monitored in the Multiannual Control Programme for Pesticides Residues (MACP), run within the EU and EFTA in/on products of plant origin.
Legal Information: TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany
Recommended products: Find a digital Reference Material for this product available on our online platform ChemisTwin®  for NMR. You can use this digital equivalent on ChemisTwin®  for your sample identity confirmation and compound quantification (with digital external standard). An NMR spectrum of this substance can be viewed and an online comparison against your sample can be performed with a few mouseclicks. Learn more here  and start your free trial .
Storage Temp. 2-8°C
UNSPSC 41116107

The following items have been added to your cart:

Choose a favorite list for this item:

Catalog Number Description Price
$

Returns/Order support

Please fill out the form below if you want to request order support from Krackeler Scientific.


Quick Order

* Required


New Year Price Updates

We are currently working diligently to update our website pricing information for the New Year. If you place an order, you will be acknowledged with any corrected pricing. If you'd like the most current information sooner, please don't hesitate to drop us an email or give us a call and we'd be happy to assist. Thank you for your patience while we are updating.

800-334-7725
office@krackeler.com


Play Video

To Request a Quote

  1. Search or Browse for items and add to them to your Shopping Cart.
  2. Click the "Request Quote" button at the bottom of the Shopping Cart page.
  3. Fill out required fields.
  4. Optionally you can convert to standard checkout mode by choosing a payment type.
  5. Click "Request Quote" at the bottom of the page.

You will be contacted with a quote.

To Order From a Quote

  1. Register and login to the website.
  2. Receive a quote from your sales representative or customer service.
  3. Have your copy of the quote in hand.
  4. Visit our quote module to search for your quote.
Back to Top