Advanced Search



Volatile Organic Compounds 1 - WP

SIAL/PE1250 - Proficiency Testing Material, Concentrate for dilution to 100 mL

Synonym: WP - VOCs

Product Type: Chemical

Catalog Number PKG Qty. Price Quantity
45-PE1250-1.2ML 1.2 mL
$88.70
1/EA
Add To Favorites
application(s) environmental
concentration in methanol
format matrix material
packaging ampule of 2 × 1.2 mL
Quality Level 100 
storage temp. 2-8°C
Application: Volatile Organic Compounds 1 - WP is a non-Potable water (NPW) PT standard, suitable for volatile organic compound testing in water pollution/wastewater.

Have any questions? Explore our FAQs .
For more information on this product, please contact our PT Service Team .
Features and Benefits: We have a vast portfolio of environmental PT schemes with "fit-for-purpose" samples to help you meet the needs of the laboratory.

Our proficiency testing (PT) program is a benchmark to:

• provide staff with an insight into their laboratory′s performance, to verify the accuracy and reliability of their testing process
• provide a comparison of performance with that of other laboratories, nationally and internationally
• test and educate staff, provide a better understanding of the impact of incorrect results and identify areas where there may be problems
• provide an independent evaluation of laboratory performance
• demonstrate to clients, colleagues and accreditation bodies that there is a commitment to quality

General description: Volatile Organic Compounds 1 - WP proficiency testing material is produced in accordance with ISO/IEC 17043:2010. Also referred to as non-Potable water or Water Pollution sample, this sample is produced according to TNI requirements. However, please note, this sample may include non-TNI analytes as well. The higher criteria from the TNI tables mimic the levels common to wastewater samples. The PT portfolio allows our test components to offer significant performance data to monitor and prove competency to customers, accreditation bodies or both.

Supelco® is a global proficiency testing (PT) provider that manufactures best-in-class environmental and pharmaceutical PT products. Most water PT samples are available as concentrates or ready-to-use volumes giving the end-user flexibility in selecting samples that will fit their exact needs. Our WP program is designed to meet the quality assurance requirements, thereby ensuring the analytical competence of your laboratory.
These samples are typically provided in duplicate for use in case of lab mishap, for QC purposes or to analyze multiple methods.

Type of PT Scheme: Water analysis - Water Pollution (WP)

Matrix: Water Pollution/Wastewater

Analyte/s: Values of analytes vary lot to lot.

All information regarding the use of Volatile Organic Compounds 1 - WP can be found in the reporting packet which will be available to download at PT Portal .
Legal Information: Supelco is a registered trademark of Merck KGaA, Darmstadt, Germany
Other Notes: Are you new to Supelco® Proficiency Testing? Be sure to register your account details  in the PT Portal before placing your order.
This will provide access to data entry, reporting packets and final reports. Registrations will be approved shortly after your order is placed. For further questions, write to us at ptservice@milliporesigma.com.

When placing your order online, please indicate your study preference under the ′your reference′ column. Available studies can be viewed at the bottom of the page.
Click here  to learn more about Quick-Turn Studies (on-demand proficiency tests that are offered depending on lot availability). The Quick-Turn results are released within 48-72 hours whereas scheduled study reports are released within 21 days.

Proficiency testing samples are presented as single blind. No values for the samples are released unti the testing period concludes.

Proficiency Testing Schedule (2022-2023)

Wastewater
WP22-2 March 23 - May 6, 2022
WP22-4 September 21 - November 4, 2022

WP23-2 March 22 – May 5, 2023
WP23-4 September 20 – November 3, 2023


Quick-Turn Study (on demand proficiency test that is offereddepending on lot availability)
Preparation Note: Description

• This PT sample is packaged as a 1.2 mL concentrate.
• The solvent for this sample is methanol.
• The PT sample is not preserved.

Sample Preparation

• Fill a 100 mL Class A Volumetric Flask to volume with organic-free reagent water.
• Open ampule PE1250-1.2ML and withdraw 20 μL of the solution using a gas-tight microsyringe.
• Inject the concentrate into the expanded area of the flask well below the surface of the water.
• Stopper the flask and mix by gentle inversion 3 times. Excessive mixing will result in loss of volatiles and should be avoided.
• This represents the sample for analysis.
• DO NOT USE a matrix simulator with this sample.
Storage and Stability: Please refer to sample label for expiration date, specific storage temperature, and specific storage conditions.
Storage Temp. 2-8°C
UNSPSC 41116107
Components 1,2,4-Trimethylbenzene 10-120 μg/L; 1,2-Dichlorobenzene 10-120 μg/L; 1,3,5-Trimethylbenzene 10-120 μg/L; 1,3-Dichlorobenzene 10-120 μg/L; 1,4-Dichlorobenzene 10-120 μg/L; Benzene 10-120 μg/L; Ethylbenzene 10-120 μg/L; m+p-Xylene 10-150 μg/L; Methyl tert-butyl ether (MTBE) 15-150 μg/L; Naphthalene 15-150 μg/L; o-Xylene 10-150 μg/L; Toluene 10-120 μg/L; Xylene, Total 20-300 μg/L

The following items have been added to your cart:

Choose a favorite list for this item:

Catalog Number Description Price
$

Returns/Order support

Please fill out the form below if you want to request order support from Krackeler Scientific.


Quick Order

* Required


New Year Price Updates

We are currently working diligently to update our website pricing information for the New Year. If you place an order, you will be acknowledged with any corrected pricing. If you'd like the most current information sooner, please don't hesitate to drop us an email or give us a call and we'd be happy to assist. Thank you for your patience while we are updating.

800-334-7725
office@krackeler.com


Play Video

To Request a Quote

  1. Search or Browse for items and add to them to your Shopping Cart.
  2. Click the "Request Quote" button at the bottom of the Shopping Cart page.
  3. Fill out required fields.
  4. Optionally you can convert to standard checkout mode by choosing a payment type.
  5. Click "Request Quote" at the bottom of the page.

You will be contacted with a quote.

To Order From a Quote

  1. Register and login to the website.
  2. Receive a quote from your sales representative or customer service.
  3. Have your copy of the quote in hand.
  4. Visit our quote module to search for your quote.
Back to Top