Hardness/TSS - Whole Volume - WP
SIAL/PE3074 - Proficiency Testing Material
Product Type: Chemical
application(s) | environmental |
concentration | in water |
format | matrix material |
packaging | bottle of 1 × 500 mL |
Quality Level | 100 |
storage temp. | 2-8°C |
Application: | Hardness/TSS - Whole Volume - WP is a non-Potable water (NPW) PT standard, suitable for hardness/TSS testing in water pollution/wastewater. Have any questions? Explore our FAQs . For more information on this product, please contact our PT Service Team . |
Features and Benefits: | We have a vast portfolio of environmental PT schemes with "fit-for-purpose" samples to help you meet the needs of the laboratory. Our proficiency testing (PT) program is a benchmark to: • provide staff with an insight into their laboratory′s performance, to verify the accuracy and reliability of their testing process • provide a comparison of performance with that of other laboratories, nationally and internationally • test and educate staff, provide a better understanding of the impact of incorrect results and identify areas where there may be problems • provide an independent evaluation of laboratory performance • demonstrate to clients, colleagues and accreditation bodies that there is a commitment to quality |
General description: | Hardness/TSS - Whole Volume - WP proficiency testing material is produced in accordance with ISO/IEC 17043:2010. Also referred to as non-Potable water or Water Pollution sample, this sample is produced according to TNI requirements. However, please note, this sample may include non-TNI analytes as well. The higher criteria from the TNI tables mimic the levels common to wastewater samples. The PT portfolio allows our test components to offer significant performance data to monitor and prove competency to customers, accreditation bodies or both. Supelco® is a global proficiency testing (PT) provider that manufactures best-in-class environmental and pharmaceutical PT products. Most water PT samples are available as concentrates or ready-to-use volumes giving the end-user flexibility in selecting samples that will fit their exact needs. Our WP program is designed to meet the quality assurance requirements, thereby ensuring the analytical competence of your laboratory. Type of PT Scheme: Water analysis - Water Pollution (WP) Matrix: Water Pollution/Wastewater Analyte/s: Values of analytes vary lot to lot. All information regarding the use of Hardness/TSS - Whole Volume - WP can be found in the reporting packet which will be available to download at PT Portal . |
Legal Information: | Supelco is a registered trademark of Merck KGaA, Darmstadt, Germany |
Other Notes: | Are you new to Supelco® Proficiency Testing? Be sure to register your account details in the PT Portal before placing your order. This will provide access to data entry, reporting packets and final reports. Registrations will be approved shortly after your order is placed. For further questions, write to us at ptservice@milliporesigma. When placing your order online, please indicate your study preference under the ′your reference′ column. Available studies can be viewed at the bottom of the page. Click here to learn more about Quick-Turn Studies (on-demand proficiency tests that are offered depending on lot availability). The Quick-Turn results are released within 48-72 hours whereas scheduled study reports are released within 21 days. Proficiency testing samples are presented as single blind. No values for the samples are released until the testing period concludes. Proficiency Testing Schedule (2022-2023) Wastewater WP22-2 March 23 - May 6, 2022 WP23-2 March 22 – May 5, 2023 Quick-Turn Study (on demand proficiency test that is offereddepending on lot availability) |
Preparation Note: | Description • This standard is packaged in a 500-mL polyethylene bottle containing approximately 500 mL of standard. • This standard is not preserved. • This standard can be stored at room temperature. Preparation Instructions • This standard has been prepared as a whole volume standard and is ready to analyze as received. • The hardness in this standard can be determined using either titration or calculation methods. • Be sure to shake this sample very well prior to taking an aliquot for the TSS determination. • It is strongly recommended that you analyze for TSS prior to removing aliquots for other analyses from the Hardness bottle. • If other analytes are to be measured prior to TSS, be sure to shake the sample very well prior to removing aliquots for any of the other parameters. • As this standard contains suspended solids, it is best to filter a portion of the standard prior to adding preservation or aspirating the sample into any instrument. • Shake the Hardness bottle very well prior to opening. • Remove aliquots for the tests that you are performing and analyze by your normal procedures. |
Storage and Stability: | Please refer to sample label for expiration date, specific storage temperature, and specific storage conditions. |
RIDADR | NONH for all modes of transport |
WGK Germany | WGK 1 |
Flash Point(F) | Not applicable |
Flash Point(C) | Not applicable |
Storage Temp. | 2-8°C |
UNSPSC | 41116107 |
Components | Calcium Hardness as CaCO3 8.7-275 mg/L; Calcium, Ca 3.5-110 mg/L; Hardness, Total as CaCO3 17-440 mg/L; Magnesium, Mg 2-40 mg/L; Total Suspended Solids, Non-Filterable Residue (TSS) 23-100 mg/L |