Advanced Search



Residual Solvents Class IIA PT

SIAL/PEP019 - Proficiency Testing Material

Product Type: Chemical

Catalog Number PKG Qty. Price Quantity
45-PEP019-1G 1 g
$257.00
1/EA
Add To Favorites
application(s) pharmaceutical
format matrix material
packaging ampule of 1 g
Quality Level 100 
suitability suitable for (suitable for 467 per USP)
Application: Residual Solvents Class IIA, as a proficiency testing material is used to determine the amounts of residual solvents in pharmaceutical drug products.

Have any questions? Explore our FAQs .
For more information on this product, please contact our PT Service Team .
Features and Benefits: We have a vast portfolio of environmental PT schemes with "fit-for-purpose" samples to help you meet the needs of the laboratory.

Our proficiency testing (PT) program is a benchmark to:

• provide staff with an insight into their laboratory′s performance, to verify the accuracy and reliability of their testing process
• provide a comparison of performance with that of other laboratories, nationally and internationally
• test and educate staff, provide a better understanding of the impact of incorrect results and identify areas where there may be problems
• provide an independent evaluation of laboratory performance
• demonstrate to clients, colleagues and accreditation bodies that there is a commitment to quality

General description: Residual Solvents Class IIA proficiency testing material is produced in accordance with ISO/IEC 17043:2010. The PT portfolio allows our test components to offer significant performance data to monitor and prove competency to customers, accreditation bodies or both.

Residual solvents in pharmaceuticals are defined as organic volatile chemicals that are used or produced in the manufacturing of drug substances, excipients, or dietary ingredients, or in the preparation of drug products or dietary supplement products.

Supelco® Pharmaceutical Proficiency Testing scheme is mainly designed to meet the needs of the pharmaceutical industry.
The pharma PT samples allow laboratories to demonstrate their competence in following compendial USP methods of analysis. They can be used to assure accreditors or auditors that the lab processes are followed accordingly. Our pharmaceutical PT scheme covers products under categories such as Chemical Tests and Assays, Physical Tests and Determinations and Microbiological Tests.

Type of PT Scheme:
Pharmaceuticals

All information regarding the use of Residual Solvents Class IIA proficiency testing standard can be found in the reporting packet which will be available to download at PT Portal .
Legal Information: Supelco is a registered trademark of Merck KGaA, Darmstadt, Germany
Other Notes: Are you new to Supelco® Proficiency Testing? Be sure to register your account details  in the PT Portal before placing your order.
This will provide access to data entry, reporting packets and final reports. Registrations will be approved shortly after your order is placed. For further questions, write to us at ptservice@milliporesigma.com.

When placing your order online, please indicate your study preference under the ′your reference′ column. Available studies can be viewed at the bottom of the page.
Click here  to learn more about Quick-Turn Studies (on-demand proficiency tests that are offered depending on lot availability). The Quick-Turn results are released within 48-72 hours whereas scheduled study reports are released within 21 days.

Proficiency Testing Schedule (2022-2023)

Pharma
PHARM22-2 April 6 - May 20, 2022
PHARM22-4 October 5 - November 18, 2022

PHARM23-2 April 5 – May 19, 2023
PHARM23-4 October 4 – November 17, 2023

Quick-Turn Study (on demand proficiency test that is offered depending on lot availability)
Preparation Note: General Instructions
1. Standard Preparation

• Add about 50 mL of water to a 100 mL volumetric flask and accurately transfer 1.0 mL of Residual Solvent Class IIA Standard to the flask, keeping the tip of the pipet below the water. Dilute to volume with water. This represents the Standard Solution.
• Add 5 mL of water to an appropriate headspace vial and accurately add 1.0 mL of Standard Solution, apply the stopper, cap, and mix.


2. Sample Preparation
• Add about 10 mL of water to a 25 mL volumetric flask and accurately transfer 1.0 mL of Residual Solvent Class IIA Sample to the flask, keeping the tip of the pipet below the water. Dilute to volume with water. This represents the PT Sample.
• Add 5.0 mL of water to an appropriate headspace vial and accurately add 1.0 mL of the PT Sample.


Analysis Procedure
• Perform the Gas Chromatography from USP general chapter <467> for Procedure A, or by using an in-house validated method for residual solvent analysis.
• Calculate and report the amount of each residual solvent that is found in the Residual Solvent Class IIA PT Sample.


Reported Data
The concentration of each residual solvent present in Residual Solvents Class IIA PT Sample (Data=Numeric)

Calculations

• C = concentration of individual residual solvent from Standard Solution Rst = Area of the individual peak from Standard Solution Rsa = Area of the individual peak from Sample Solution
• Class IIA PT Concentration = C*(Rsa/Rst)

Note: 1 ampule of product PHR1064 (Residual Solvents Mixture - Class IIA) is being supplied as the standard for this proficiency test. The COA for this material can be downloaded at sigmaaldrich.com using the lot number that you receive.
Storage and Stability: Please refer to sample label for expiration date, specific storage temperature, and specific storage conditions.
WGK Germany nwg
UNSPSC 41116107
Components Chlorobenzene .0001-720 ppm; Cyclohexane .0001-7000 ppm; 1,4-Dioxane (1,4- Diethyleneoxide) .0001-760 ppm; Ethylbenzene .0001-740 ppm; Methanol .0001-6000 ppm; Methylcyclohexane .0001-2500 ppm; Methylene chloride (Dichloromethane) .0001-1200 ppm; Tetrahydrofuran (THF) .0001-1500 ppm; Toluene .0001-2000 ppm; o-Xylene .0001-2000 ppm; 1,2-Dichloroethylene, total .0001-3000 ppm; m+p-Xylene .0001-3000 ppm; Acetonitrile .00001-820 ppm

The following items have been added to your cart:

Choose a favorite list for this item:

Catalog Number Description Price
$

Returns/Order support

Please fill out the form below if you want to request order support from Krackeler Scientific.


Quick Order

* Required


New Year Price Updates

We are currently working diligently to update our website pricing information for the New Year. If you place an order, you will be acknowledged with any corrected pricing. If you'd like the most current information sooner, please don't hesitate to drop us an email or give us a call and we'd be happy to assist. Thank you for your patience while we are updating.

800-334-7725
office@krackeler.com


Play Video

To Request a Quote

  1. Search or Browse for items and add to them to your Shopping Cart.
  2. Click the "Request Quote" button at the bottom of the Shopping Cart page.
  3. Fill out required fields.
  4. Optionally you can convert to standard checkout mode by choosing a payment type.
  5. Click "Request Quote" at the bottom of the page.

You will be contacted with a quote.

To Order From a Quote

  1. Register and login to the website.
  2. Receive a quote from your sales representative or customer service.
  3. Have your copy of the quote in hand.
  4. Visit our quote module to search for your quote.
Back to Top