Hellma® liquid calibration standards set
SIAL/Z802204 - UV1, UV12, UV6, UV9, UV60, UV600, UV14, UV5, complete set for testing photometers according to Ph. Eur.
Product Type: Equipment/Book
application(s) | food and beverages petroleum pharmaceutical plastics |
format | neat |
grade | certified reference material |
manufacturer/tradename | Hellma 667-UV003 |
Quality Level | 100 |
General description: | Certified set of liquid Hellma® calibration standards to enable the checking of spectrophotometers with respect to wavelength accuracy, photometric accuracy, stray light and spectral resolution at wavelengths from 198 nm to 650 nm. Consisting of : 667-UV100 (see Z802425, for stray light) 667-UV200 (see Z802530, for spectral resolution) 667-UV305 (see Z802654, for photometric accuracy) 667-UV5 (see Z802328, for wavelength accuracy) Wavelength [nm]: A: 235; 257; 313; 350; 430 W: 241; 287; 361; 536; 640 S: 200 (cut-off) R: Scan 265 - 270 This calibration set consists of eight liquid filters which enable the complete checking of the spectrophotometer according to European Pharmacopeia. They are designed for use with the standard 10 mm cell holder provided with spectrophotometers. The set is supplied in a sturdy wooden case. For identification purposes a number is engraved on each filter. The absorbance values and/or peak position wavelengths of every filter are quoted in the accompanying calibration certificate. |
Legal Information: | Hellma is a registered trademark of Hellma GmbH |
Other Notes: | The most current version of Hellma's handling guideslines for these calibration standards can be accessed on the Hellma Analytics web site. |
Symbol | GHS02,GHS07,GHS08,GHS09 |
Signal word | Danger |
Hazard statements | H225 - H304 - H315 - H319 - H336 - H361fd - H373 - H411 |
Precautionary statements | P210 - P273 - P301 + P310 - P303 + P361 + P353 - P305 + P351 + P338 - P331 |
Hazard Codes | F,Xn,N |
Risk Statements | 11-36/38-48/20-51/53-62-65-67 |
Safety Statements | 16-26-36/37-61-62 |
RIDADR | UN 3316 9 |
Flash Point(F) | -14.8 °F - closed cup |
Flash Point(C) | -26.0 °C - closed cup |
UNSPSC | 12000000 |
Components | Hellma® liquid calibration standards, UV5, for testing the wavelength accuracy 1; Hellma® liquid calibration standards set, UV1, UV12, for testing for stray light acc. to Ph. Eur. 1; Hellma® liquid calibration standards set, UV6, UV9, for testing the spectral resolution acc. to Ph. Eur. 1; Hellma® liquid calibration standards set, UV60, UV600, UV14, for testing the photometric accuracy 1 |