Sigma Cat.No. | Description |
---|---|
Z802727 | Hellma® absorption cuvettes, Flow-through cells High Performance Quartz Glass, spectral range 200-2500 nm, pathlength 10 mm, chamber volume 750 μL |
Z802751 | Hellma® absorption cuvettes, standard cells, Macro High Performance Quartz Glass, Suprasil® quartz, spectral range 200-2,500 nm, pathlength 10 mm, chamber volume 3,500 μL |
Z802778 | Hellma® fluorescence cuvettes, Micro High Performance Quartz Glass, spectral range 200-2500 nm, pathlength 10x2 mm, chamber volume 400 μL |
Z802786 | Ring holders for Specac® mini-pellet press |
Z802794 | Hellma® absorption cuvettes, standard cells, Macro Special Optical Glass, spectral range 320-2500 nm, pathlength 2 mm, chamber volume 700 μL |
Z802808 | Hellma® TrayCell™ cap pathlength 1 (factor 10) mm ± 0.02 mm, chamber volume 3-5 μL |
Z802867 | Hellma® absorption cuvettes, standard cells, Micro Special Optical Glass, spectral range 320-2,500 nm, pathlength 10 mm, chamber volume 700 μL |
Z802875 | Hellma® fluorescence cuvettes, Micro High Performance Quartz Glass, spectral range 200-2500 nm, pathlength 10x2 mm, chamber volume 700 μL |
Z802891 | Hellma® absorption cuvettes, standard cells, Macro Special Optical Glass, spectral range 320-2500 nm, pathlength 5 mm, chamber volume 1750 μL |
Z802948 | Hellma® absorption cuvettes, Flow-through cells High Performance Quartz Glass, spectral range 200-2500 nm, pathlength 10 mm, chamber volume 450 μL |
Z803006 | Hellma® absorption cuvettes, standard cells, Macro Special Optical Glass, spectral range 320-2500 nm, pathlength 100 mm, chamber volume 35000 μL |
Z803014 | Hellma® TrayCell™ cap pathlength 2 (factor 5) mm ± 0.02 mm, chamber volume 6-10 μL |
Z803049 | Hellma® absorption cuvettes, Flow-through cells Suprasil® quartz, spectral range 200-2500 nm, pathlength 10 mm, chamber volume 450 μL |
Z803073 | Hellma® fluorescence cuvettes, standard cells, Macro High Performance Quartz Glass, spectral range 200-2,500 nm, pathlength 10x10 mm, chamber volume 3,500 μL |
Z803103 | Specac® Atlas 15T manual hydraulic press |
Z803111 | Hellma® absorption cuvettes, standard cells, Macro High Performance Quartz Glass, spectral range 200-2500 nm, pathlength 1 mm, chamber volume 350 μL |
Z803138 | Hellma® TrayCell™ cap pathlength 0.1 (factor 100) mm ± 0.02 mm, chamber volume 0.7-3 μL |
Z803197 | Hellma® fluorescence cuvettes, standard cells, Macro High Performance Quartz Glass, spectral range 200-2,500 nm, pathlength 10x10 mm, chamber volume 3,500 μL |
Z803200 | Hellma® cuvettes for light-scattering measurements High Performance Quartz Glass, I.D. 8 mm, spectral range 200-2500 nm, chamber volume 2800 μL |
Z803227 | Hellma® absorption cuvettes, standard cells, Macro High Performance Quartz Glass, spectral range 200-2500 nm, pathlength 2 mm, chamber volume 700 μL |
Z803251 | Hellma® liquid calibration standards UV20, for testing the photometric accuracy |
Z803308 | Hellma® cylindrical absorption cuvettes High Performance Quartz Glass, spectral range 200-2,500 nm, pathlength 10 mm, chamber volume 2,800 μL |
Z803316 | Hellma® cuvettes for light-scattering measurements High Performance Quartz Glass, I.D. 8 mm, spectral range 200-2500 nm, chamber volume 2800 μL |
Z803324 | Lightweight die for Specac® Atlas 15T presses size 40 mm |
Z803405 | Hellma® cylindrical absorption cuvettes High Performance Quartz Glass, spectral range 200-2,500 nm, pathlength 20 mm, chamber volume 5,600 μL |
Z803421 | Specac® Benchmark baseplate for Thermo Nicolet 500, 700, 710, 740, 800, 5PC, 5SXC, Magna, Protege, Avatar, Nexus, Impact, 6700, iS10, iS50 |
Z803448 | Hellma® absorption cuvettes, standard cells, Macro High Performance Quartz Glass, spectral range 200-2500 nm, pathlength 40 mm, chamber volume 14000 μL |
Z803510 | Hellma® cylindrical absorption cuvettes High Performance Quartz Glass, spectral range 200-2,500 nm, pathlength 50 mm, chamber volume 14,000 μL |
Z803545 | Hellma® absorption cuvettes, standard cells, Macro High Performance Quartz Glass, spectral range 200-2500 nm, pathlength 100 mm, chamber volume 35000 μL |
Z803634 | Hellma® cylindrical absorption cuvettes High Performance Quartz Glass, spectral range 200-2,500 nm, pathlength 100 mm, chamber volume 28,000 μL |
Z803669 | Hellma® absorption cuvettes, cells for magnetic stirrers High Performance Quartz Glass, spectral range 200-2500 nm, pathlength 10 mm, chamber volume 3500 μL |
Z803758 | Specac® Omni Cell demountable cell for IR spectroscopy |
Z803774 | Hellma® absorption cuvettes, cells for magnetic stirrers High Performance Quartz Glass, spectral range 200-2500 nm, pathlength 10 mm, chamber volume 1500 μL |
Z803812 | Hellma® absorption cuvettes, Flow-through cells optical glass, spectral range 320-2500 nm, pathlength 10 mm, chamber volume 30 μL |
Z803855 | Specac® Omni Cell windows NaCl, 41mm x 23mm x 4mm, for Omni Cell |
Z803871 | Hellma® cylindrical absorption cuvettes High Performance Quartz Glass, spectral range 200-2500 nm, pathlength 1 mm, chamber volume 280 μL |
Z803898 | HPLC Autosampler Standards certified reference material |
Z803979 | Specac® Omni Cell windows KBr, 41mm x 23mm x 4mm, for Omni Cell |
Z803995 | Hellma® cylindrical absorption cuvettes High Performance Quartz Glass, spectral range 200-2500 nm, pathlength 2 mm, chamber volume 560 μL |
Z804002 | UV Absorbance Linearity Standards certified reference material |
Z804088 | Specac® Omni Cell windows CaF2, 41mm x 23mm x 4mm, for Omni Cell |
Z804126 | UV Low Wavelength Standards certified reference material |
Z804142 | Hellma® liquid calibration standards UV80, for testing the photometric accuracy |
Z804193 | Specac® Omni Cell windows BaF2, 41mm x 23mm x 4mm, for Omni Cell |
Z804223 | UV Multi Wavelength Standards certified reference material |
Z804304 | Specac® Omni Cell windows ZnSe, 41mm x 23mm x 2mm, for Omni Cell |
Z804355 | Hellma® liquid calibration standards UV25, for testing the wavelength accuracy |
Z804363 | Hellma® absorption cuvettes, Flow-through cells Special Optical Glass, spectral range 320-2500 nm, pathlength 10 mm, chamber volume 30 μL |
Z804428 | Specac® Omni Cell windows KRS-5, 41mm x 23mm x 4mm, for Omni Cell |
Z804444 | Hellma® cylindrical absorption cuvettes High Performance Quartz Glass, spectral range 200-2500 nm, pathlength 0.2 mm, chamber volume 170 μL |