Proteomics Dynamic Range Standard Set
SIGMA/UPS2 - Protein Mass Spectrometry Calibration Standard
Synonym: Universal Proteomics Standard for Mass Spectrometry
EC Number: 232-650-8
Product Type: Chemical
biological source | human |
concentration | 10.6 μg/ampule protein |
quality | Protein Mass Spectrometry Calibration Standard |
Quality Level | 200 |
shipped in | wet ice |
storage temp. | −20°C |
Application: | Proteomics Dynamic Range Standard Set has been used in the intensity-based absolute quantification (iBAQ) of E .coli proteins, embryonic stem cells (ESCs) and neuronal precursor cells (NPCs) proteomes. It has also been used as a standard to spike HeLa cells for label-free quantification. |
Application: | The Proteomics Dynamic Range Standard Set can be used to standardize and/or evaluate mass spectrometric (e.g., LC-MS/MS, MALDI-TOF-MS, etc.) and electrophoretic analysis conditions prior to the analysis of complex protein samples. UPS2 can be used to bracket precious experimental data sets between runs of a known complex standard sample. This allows confirmation of the robustness of the analysis method and stability of the instrument employed. Additionally, laboratories generating or comparing mass spectrometric data derived from poorly defined samples can use UPS2 as an external reference to assist with the evaluation of results and experimental methodology. Proteomics Dynamic Range Standard Set has been used for the quantification of dynamic range universal protein standard on Orbitrap Analyzer using all ion fragmentation. It has been used as a standard for intensity-based absolute quantification of proteins (iBAQ) in LC-MS (liquid chromatography-mass spectrometry)/MS analysis. |
General description: | The Proteomics Dynamic Range Standard Set is produced from a mixture of 48 individual human source or human sequence recombinant proteins, each of which has been selected to limit heterogeneous post-translational modifications (PTMs). The protein standard is formulated from 6 mixtures of 8 proteins to present a dynamic range of 5 orders of magnitude, ranging from 50 pmoles to 500 amoles. Each protein has been quantitated by amino acid analysis (AAA) prior to formulation. |
Symbol | GHS07,GHS08 |
Signal word | Danger |
Hazard statements | H315 - H319 - H334 - H335 |
Precautionary statements | P261 - P264 - P271 - P280 - P302 + P352 - P305 + P351 + P338 |
Hazard Codes | Xn |
Risk Statements | 36/37/38-42 |
Safety Statements | 22-24-26-36/37 |
RIDADR | NONH for all modes of transport |
WGK Germany | WGK 3 |
Flash Point(F) | Not applicable |
Flash Point(C) | Not applicable |
Storage Temp. | −20°C |
UNSPSC | 12352200 |
Components | Trypsin from porcine pancreas, Proteomics Grade, BioReagent, Dimethylated 20 μg |